| FEATURES: |
 |
- 50 MHz to 3.5 GHz
frequency range.
- For isotropic
measurements of electromagnetic fields.
- Non-directional
(isotropic ) measurement with three-channel
measurement probe.
- High dynamic range
due to three-channel digital results processing.
- Configurable alarm
threshold and memory function.
- Easy to use
|
| APPLICTIONS |
- High frquency (RF)
electromagnetic wave field strength measurement.
- Mobil phone base
station antenna ratenna radiation power density
measurement.
- Wireless
communication applications(CW , TDMA , GSM ,
DECT).
|
- Wireless LAN(Wi-Fi)
detection, installation.
- Spy camera,
wireless bug finder.
- Cellular/Cordless
phone radiation safety level.
- Microwave oven
leakage detection.
- Personal living
environment EMF safety.
- RF power
measurement for fransmitters.
|
| SPECIFICATION: |
|
|
ELRCTRICAL
SPECIFICATIONS
|
| Sensor
type |
Electric
field (E) |
| Frequency
range |
50MHz
to 3.5 GHz |
| Directional
characteristic |
Isotropic,
3-dimensional |
| Measurement
range(CW signal>50MHz) |
38mV/m
to 11V/m |
| Absolute
error(@1V/m and 50MHz) |
¡À
1.0dB |
| Frequency
response(taking into accountb typ.CAL
factor) |
¡À
1.0dB (50MHz to 1.9 GHz) , ¡À2.4dB(1.9GHz to
35GHz) |
| Isotropy
deviation |
Type.
¡À1.0dB ì¶ f>50
MHz |
| Overload
limit |
4.2W/m2
(40 V/m) |
| Temperature
response(0 to 50 ¡æ) |
¡À
1.5dB |
| Note |
Unless
otherwise stated, all specifications hold
under the following assumptions:
Sinusoidal
signals; device in far-field of a source;
probe head pointing toward source;ambient
temperature +23 ¡æ¡À3 ¡æ;relative air
humidity 25% to 75%.
|
|
| Measurement
methd |
Digital
, triaxial measurement |
| Directional
characteristic |
Isotropic,
triaxial |
| Measurement
range selection |
One
continuous range |
| Display
resolution |
0.1mV/m,
0.1 ¦ÌA/m, 0.01 ¦ÌW/m2 |
| Setting
time |
Typically
1s ( 0 to 90% of meas. value) |
| Display
refresh rate |
Typically
400mS
|
| Display
type |
LCD
4 digit |
| Audible
alarm |
Buzzer |
| Measurement
units |
mV/m
, V/m , ¦ÌA/m , mA/m , ¦ÌW/m2 , mW/m2 |
| Measurement
display value |
Instantaneous
measured value, maximum value or average
value since power-on. |
| Measurement
average time(in per-set steps) |
4s
to 15 minutes |
| Measurement
alarm function |
Adjustable
threshold with ON/OFF |
| Measurement
calibration factor CAL |
Adjustable |
| Manual
data memory and read storage |
99
sets ( only recall by meter ) |
| Battery |
9V |
| Battery
life |
>15
hours |
| Accessory |
9V
battery, carrying case & mamaul |
|
|
|