| FEATURES: |
 |
- 10 Display Easy -
to - View LCD Screen.
- Connectors for 4
Current Sensing Clamps.
- 1P2W, 1P3W, 3P3W2M
& 3P4W Power Measurement.
- True RMS Sensing.
- Power KW, KVAR,
KVA, PF, ¦È ,Hz, & Energy KWh, KVARh &
KVAh Measurement.
- Phase sequency
indicator function.
- Backlight display
function.
- Manual Data Memory
and Read (99 sets).
- Data Logging
(512KB Memory, 20,000 sets)
- Programmable
Trigger - Points and Start / Stop Time.
- RS-232 Optical
Interface with three phase voltage / current
Waveform display and Harmonic analysis.
- Easy - to - use
Push - Button Operation.
- Light Weight,
Portable Design.
|
| SPECIFICATION: |
|
|
Ranges
|
Method
|
Accuracy
|
Input
impedance
|
|
600.0V
|
True RMS
|
¡À 0.5%rdg ¡À
10dgts (>30V)
|
2M ¦¸
|
|
|
Ranges
|
Method
|
Accuracy
|
|
250A ¡¢
500A ¡¢
1000A
|
True
RMS
|
¡À
0.5%rdg ¡À 10dgts+clamp on sensor
specifications
|
|
| Active Power
Measurement (KW) |
|
Ranges
|
Accuracy
|
Effect
of power factor
|
|
600.0KW
|
¡À 0.5%rdg ¡À
10dgts+clamp on sensor specifications
|
¡À
0.1%rdg
|
|
| Reactive Power
Measurement (KVAR) |
|
Ranges
|
Accuracy
|
Effect
of power factor
|
|
600.0KVAR
|
¡À 0.5%rdg ¡À
10dgts+clamp on sensor specifications
|
¡À 0.1%rdg
|
|
| Apparent Power
Measurement (KVA) |
|
Ranges
|
Accuracy
|
|
600.0KVA
|
¡À 0.5%rdg ¡À
10dgts+clamp on sensor specifications
|
|
| Power
Integration Measurement |
|
Power
Integration
|
Resolution
|
Accuracy
|
|
0.0KWh to
9999MWh
|
0.1KWh
|
¡À 0.5%rdg ¡À
10dgts+clamp on sensor specifications
|
|
0.0Kvarh to
9999Mvarh
|
0.1Kvarh
|
|
0.0KVAh to
9999MVAh
|
0.1KVAh
|
|
|
Ranges
|
Accuracy
|
Polarity
display
|
|
-1.000(lead)
to 0.000 to + 1.000 (lag)
|
¡À
1dgt for each calculation from measured
values
|
When the
current lags the voltage unsigned ; when
the current leads the voltage :
"-".
|
|
|
Ranges
|
Measurement
source
|
Accuracy
|
|
40Hz to 100Hz
|
Voltage U1
|
¡À 0.5%rdg ¡À
1dgt
|
|
| Size |
235(L)x116(W)x54(H)mm
(9.3"Lx4.6"Wx2.1"H) |
| Operating
Temperature and Humidity |
0
¡æ to 50 ¡æ (32 ¨H to 122 ¨H ) R.H. <
80% non-condensing |
| Storage
Temperature and Humidity |
-
10 ¡æ to 60 ¡æ (14 ¨H to 140 ¨H ) R.H.
< 70% non-condensing |
| Accessories |
Instruction
manual , Softwar CD rom / Optical RS-232
interface , Deluxe carrying case , Battery (
¡°AA¡± 1.5V ¡ä 8pcs ) , AC adaptor (110V
12V ; 220V 12V) , 4pcs
current clamp transducer (1, 2, 3, 4 cable
length 3 meters) (1000A AC, jaw opening
40mm) , 4pcs crocodiles test leads (blue,
yellow, red, black, wire length 3 meters)
|
|
|
|