| FEATURES: |
 |
- 3 f 4W, 3 f 3W, 3
f Balanced, 1 f 2W, and 1 f 3W Power
Measurement.
- AC+DC true power,
and True RMS AC Voltage and Current
- AC+DC 2000A, AC
600V, DC 800V
- AC+DC 1200KW(1 f
), AC+DC 2000KW (3 f )
- Dual Display V+Hz,
A+Hz, W+PF, KVA+KVAR, V+A
- Phase Angle
Measurement
- 3 f RST(L1L2L3)
Sequence Indication.
- Memory of 4
records.
- DCA/DCW Auto Zero
when power clamp powering on.
- AC/DC Auto
Detection.
- Auto range.
|
| SPECIFICATION: |
|
| AC+DC True
Power (PF 0.2-1.0, 3 ¦µ 3W, 3 ¦µ 4W, 1 ¦µ
2W, and 1 ¦µ 3W) |
|
Range
|
Resolution
|
Accuracy(of
rdg)
|
Input
Range
|
|
0-99.9KW
|
0.1KW
|
+/- 2.0% +/-
0.05KW
|
AC 600V, DC
800V, ACA/DCA 2000A
|
|
100-999.9KW
|
0.1KW
|
+/- 2.0% +/-
0.5KW
|
AC 600V, DC
800V, ACA/DCA 2000A
|
|
1000-1200KW
|
1KW
|
+/- 2.0% +/-
5KW
|
AC 600V, DC
800V, ACA/DCA 2000A
|
|
| AC+DC True
Power (Power Factor 0.2-1.0, 3 ¦µ Balanced
Power) |
|
Range
|
Resolution
|
Accuracy(or
rdg)
|
Input
Range
|
|
0-99.99KW
|
0.01KW
|
+/- 2.0% +/-
0.5KW
|
AC 600V, DC
800V, ACA/DCA 2000A
|
|
100-999.9KW
|
0.1KW
|
+/- 2.0% +/-
0.5KW
|
AC 600V, DC
800V, ACA/DCA 2000A
|
|
1000-1200KW
|
1KW
|
+/- 2.0% +/-
5KW
|
AC 600V, DC
800V, ACA/DCA 2000A
|
|
POWER
FACTOR (PF)
PF=KW/KVA
|
|
| AC+DC Voltage
(True RMS, Crest Factor<4, Autorange,
Overload Protection 800VAC for all ranges) |
|
Range
|
Resolution
|
Accuracy(of
reading)
|
Input
Impedance
|
|
DC, 50/60Hz
|
40-400Hz
|
|
0-200A
|
0.1V
|
+/- 1.5% +/- 5
dgts
|
+/- 2.0% +/- 5
dgts
|
10M ¦¸
|
|
200-500A
|
0.1V
|
+/- 1.5% +/- 5
dgts
|
+/- 2.0% +/- 5
dgts
|
10M ¦¸
|
|
500-600VAC
500-800VDC
|
1V
|
+/- 1.5% +/- 5
dgts
|
+/- 2.0% +/- 5
dgts
|
10M ¦¸
|
|
| AC+DC Current
(True RMS, Crest Factor<4) |
|
Range
|
Resolution
|
Accuracy(of
reading)
|
Overload
Protection
|
|
DC, 50/60 Hz
|
40-400Hz
|
|
0-200A
|
0.1A
|
+/- 1.5% +/- 5
dgts
|
+/- 2.0% +/- 5
dgts
|
AC 3000A
|
|
200-500A
|
0.1A
|
+/- 2.0% +/- 5
dgts
|
+/- 2.5% +/- 5
dgts
|
AC 3000A
|
|
500-2000A
|
1A
|
+/- 2.5% +/- 5
dgts
|
+/- 3.0% +/- 5
dgts
|
AC 3000A
|
|
AC+DC
KVA (Apparent Power)
(KVA)=VxA/1000
AC+DC
KVAR(Reactive Power)
(KVAR)=

|
|
| Phase Angle
(must zero current reading before
measurement) |
|
Range
|
Accuracy
|
Sensitivity
|
Remark
|
|
50/60Hz
|
+/- 2.0 ¡ã
|
V>100V,
A>10A
|
Zero Crossing
Detection
|
|
| Frequency
(if<10 Hz, Hz=0) |
|
Range
|
Accuracy
|
Sensitivity
|
|
50/60Hz
|
+/- 2dgts
|
V: >1V, A:
>5A
|
|
10-400Hz
|
+/- 0.5% +/-
2dgts
|
V: >1A, A:
>5A
|
|
| Conductor
Size |
Cable f 55mm.
(approx.)
Bus Bar 65mm(D)x24mm(W) |
| Battery
Type |
9V |
| Display |
2x4 Digits
Dual Display LCD |
| Range
Selection |
Auto |
| Overload
Indication |
OL |
| Power
Consumption |
28mA (approx.) |
| Low
battery Indication |
 |
| Sampling
Time |
0.5 sec. (V
and A)
1.6 sec.(W) |
| Operating
Temperature |
4 o to 50 o C |
| Operating
Humidity |
Less than 85%
relative |
| Altitude |
up to 2000M |
| Storage
Temperature |
-20 o C to 60
o |
| Storage
Humidity |
Less than 75%
relative |
| Dimensions |
271mm(L)x112mm(W)x46mm(H)
10.7"(L)x4.4"(W)x1.8"(H) |
| Weight |
647g/22.8 oz
(Battery included) |
|
|
|